Reset Counter and Total Usage on Asset After Rebuild
You can reset usage of the counter category on your asset. You can use this option, to start counting usage on the asset from 0. It might happen after asset rebuild.
Action is hidden by default.
Reset can not be done when:
At least one work order exists for the frequency that is using this counter category
At least one work order is added to the work order planning worksheet triggered by the frequency that is using this counter category
All related documents, that are using this counter category, will be updated and reset to start counting from 0 point:
Work Order Frequencies
Work Order Sequences
Work Order Group Frequencies
Work Order Group Sequences
Important:
All frequencies and sequences will be reset to 0 point - keep in mind that if your frequencies have Do not trigger before usage set up with some value - these values (in the Do not trigger before usage field) will not be updated. In such cases you will need to inspect and update these frequencies manually.
Reset does not impact on asset warranties applied to this asset - if any warranty is counter based - reset will not update counter limit on the warranty.
Reset does not impact on Starting Point on Work Order Sequences.
Reset impact on Forced Next Step on Work Order Group Sequences - this value is removed and the whole sequence starts from the beginning.
When resetting the asset usage - you are informed about all documents that are currently using this counter category as a frequency. Below you have an example where the counter category is used on all possible places.